Reading your meter

There are several different types of electricity meters. The following information will show you how to read the different types.

Clock Face (Pointer) Meters

This meter has up to six clock faces. There is one hand on each clock face. The clock faces have numbers 0 to 9 and alternate between rotating clockwise and anti-clockwise.

Start reading from the left hand dial (A) and read each dial in succession to the right. When a dial hand points between two numbers, write down the lower of the two numbers. If it points between 0 and 1 write down 0 and if it points between 9 and 0 write down 9.

Dial face (Pointer) Meters

When a dial hand appears to be exactly on a number, as with dial (A), look at the next dial to the right to see if it has passed zero. If the next dial has not passed zero, as with dial (B), then the reading for the first dial is the lower number. In this example the reading for dial (A) is 7.

In this example the reading is 7-9-8-6-7.

Digits (Cyclometer) Display Meters - Single Rate

This meter gives a direct readout of the total amount of electricity used. Read the numbers in the same sequence as shown on the meter.

Digits (Cyclometer) Display Meters - Single Rate

In this example the reading is: 7 - 2 - 4 - 2 - 1

Digits (Cyclometer) Display Meters - Single Rate

In this example the reading is: 0 - 3 - 8 - 7 - 7

Digits (Cyclometer) Display Meters - Dual Rate

These meters are similar to the Single Rate Digits (Cyclometer) Display Meters but with a dual display. Firstly, record the reading for the top display, followed by the reading for the bottom display.

In this example, the meter shows two displays - H (High/Peak) and L (Low/Off Peak). Note some meters may have the H and L displays reversed.

The reading for this example is:

Digits (Cyclometer) Display Meters - Dual Rate

H 0 - 0 - 3 - 1 - 2


L 0 - 0 - 2 - 9 - 5 

Electronic Digital Display Meters

This meter will automatically cycle through the various meter readings. It is not necessary to press any buttons to read this meter, simply watch as the various meter readings appear.

If a reading is missed simply wait and it will be displayed again. Enter all readings in the boxes provided.

This meter will also display readings for ‘test’, ‘date’, ‘time’ and ‘program ID’. Enter all of these readings in the boxes provided as well.

If ‘error codes E and F’ appear then there is a problem with the meter. Please report these codes on the meter reading sheet.

Electronic Digital Display Meter

In this example the reading is 0 - 0 - 4 - 7 - 6 - 3.

Solar Meters (Inverter Energy System Meters)

Your meter model type is displayed on the front panel label on the front of the meter. The digital display has two sections, the Display ID (or code) and the Display Data (or the actual reading).

It is not necessary to push any buttons on the meter to obtain the reading. A test screen will initially display as a series of 8s. This will ensure the digital display is working correctly.

The specific data displayed on your meter depends on your electricity supply. For example, do you have separate hot water metering, or is your supply single or multiphase?

Solar energy generated will be used by appliances and any excess generation will be recorded on an instantaneous basis on the appropriate display ID.

The following information will show you how to read the different solar meter types.

EM1000 Meter – meter used for single tariff installations (Tariff 11 or 20) EM1000 Meter display

Display Data Display ID Explanation of Reading
Display Test Screen

A B C D

The test displays first as a series of 8s
Total Import kWh (from Ergon)

(Blank)

Energy (kWh) used from the grid
Total Export kWh (excess to Ergon)

-

Excess energy (kWh) sent back to the grid (occurs when appliance usage is less than energy generated by the solar panels)

 

EM1200 Meter – meter used for two tariff installations (Tariff 11, 33 or 31)

 EM1200 Meter display

Display Data Display ID Explanation of Reading
Display Test Screen

88

The test displays first as a series of 8s
Date

02

Present date
Time

03

Present time
Rate A kWh Element 1 (Peak)
*Only applicable if primary tariff is time of use, eg T62 or T22

04*

Energy (kWh) used from the grid between 7am- 9pm Monday-Friday - High Rate
Rate C kWh Element 1 (Off Peak)
*Only applicable if primary tariff is time of use, eg T62 or T22

05*

Energy (kWh) used from the grid between 9pm- 7am Monday-Friday and all weekend - Low Rate
Total Import kWh Element 1
(from Ergon Energy)

06

Energy (kWh) used from the grid on primary tariff (eg Tariff 11)
Sum of 04 & 05 if applicable
Total Export kWh Element 1 & Element 2
(excess to Ergon Energy)

07

Excess energy (kWh) sent back to the grid (occurs when appliance usage is less than energy generated by the solar panels)
Total Import kWh Element 2
(from Ergon Energy)

09

Energy (kWh) used on secondary tariff (ie Tariff 31 or 33)
Program ID

10

Meter program number - Ergon Energy use only

NOTE: New EM1200 meters manufactured from 2012 will not have the Test Display or the Date and Time displays.

 

MK 10 Meter – multipurpose installations (Tariff 11, 20, 22 or 62)

 MK 10 Meter display

Display Data Display ID Explanation of Reading
Display Test Screen

888

The test displays first as a series of 8s
Date

001

Present date
Time

002

Present time
Total kWh
(from Ergon Energy)

003

Total energy (kWh) used from the grid. Equals sum of 004, 005 and 006 
Rate A kWh
(from Ergon Energy)

004

Energy (kWh) used from the grid between 7am- 9pm Monday-Friday
Rate B kWh
(from Ergon Energy)

005

Energy (kWh) used from the grid between 9pm- 11pm Monday-Friday
Rate C kWh
(from Ergon Energy)

006

Energy (kWh) used from the grid at all other times
Previous Maximum kW

011

Previous demand - Ergon Energy use only
Current Cumulative kW

012

Current demand - billing use for demand trials
Current Maximum kW

013

Highest maximum demand recorded since last reset - Ergon Energy use only
Demand Reset Count

040

Number of times demand reset - Ergon Energy use only
Program ID

042

Meter program number - Ergon Energy use only
Alarm

057

Displays alarm code - Ergon Energy use only
Total kWh Export
(excess to Ergon Energy)

114

Excess energy (kWh) sent back to grid (occurs when appliance usage is less than energy generated by the solar panels).

 

Q4 Meter – multipurpose installations (Tariff 11, 20, 22 or 62)

Q4 Meter display

Display Data Display ID Explanation of Reading
Display Test Screen

888

The test displays first as a series of 8s
Date

001

Present date
Time

002

Present time
Total kWh
(from Ergon Energy)

003

Total energy (kWh) used from the grid. Equals sum of 004, 005 and 006 
Rate A kWh
(from Ergon Energy)

004

Energy (kWh) used from the grid between 7am- 9pm Monday-Friday
Rate B kWh
(from Ergon Energy)

005

Energy (kWh) used from the grid between 9pm- 11pm Monday-Friday
Rate C kWh
(from Ergon Energy)

006

Energy (kWh) used from the grid at all other times
Previous Cumulative kW

011

Previous demand - Ergon Energy use only
Current Cumulative kW

012

Current demand - billing use for demand trials
Current Maximum kW

013

Highest maximum demand recorded since last reset - Ergon Energy use only
Demand Reset Count

040

Number of times demand reset - Ergon Energy use only
Program ID

042

Meter program number - Ergon Energy use only
Total kWh Export
(excess to Ergon Energy)

114

Excess energy (kWh) sent back to grid. Equals sum of 115, 116 and 117 
Rate A kWh Export
(excess to Ergon Energy)

115

Excess energy (kWh) sent back to the grid between 7am- 9pm Monday-Friday
Rate B kWh Export
(excess to Ergon Energy) 

116

Excess energy (kWh) sent back to the grid between 9pm- 11pm Monday-Friday
Rate C kWh Export
(excess to Ergon Energy)

117

Excess energy (kWh) sent back to the grid at all other times

NOTE: Displays 115 – 117 discontinued in IES meters manufactured from September 2009.